Series arc faults in AC and DC electrical circuits. Characterization and detection methods
2013
This paper analyzes the problem of the arc faults in both AC and DC low voltage electrical circuits. The state-of-the-art of the arc fault detection methods is analyzed together with the UL 1699 and UL 1699B Standard requirements for protection devices against arc faults (AFCIs). An experimental characterization is carried out of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The experimental measurements are carried out on a proper test bench, which has been developed in order to reproduce significant arcing conditions, in accordance with the UL 1699 Standard requirements.
Arc Fault Detection Method Based on CZT Low-Frequency Harmonic Current Analysis
2017
This paper presents a method for the detection of series arc faults in electrical circuits, which has been developed starting from an experimental characterization of the arc fault phenomenon and an arcing current study in several test conditions. Starting from this, the authors have found that is it possible to suitably detect arc faults by means of a high-resolution low-frequency harmonic analysis of current signal, based on chirp zeta transform, and a proper set of indicators. The proposed method effectiveness is shown by means of experimental tests, which were carried in both arcing and nonarcing conditions and in the presence of different loads, chosen according to the UL 1699 standard…
Caratterizzazione e metodi di riconoscimento degli arc faults per applicazioni in sistemi di bassa tensione
2013
ARC FAULT DETECTION EQUIPMENT AND METHOD USING LOW FREQUENCY HARMONIC CURRENT ANALYSIS
2012
An arc fault detection circuit includes a current sensing circuit coupled to a line conductor carrying a current. The current sensing circuit operates to sense current and output data indicative of the sensed current. A processing circuit implements a frequency transform algorithm to transform the output data to frequency data in a low frequency range and with a high spectral resolution where a minimum short time observation window is concerned. The processing circuit identifies an arc fault condition on the line conductor by identifying differences in said frequency data between at least two subsequent observation windows and identifying characteristics which exceed thresholds.
A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
Experimental characterization of series arc faults in AC and DC electrical circuits
2014
This paper presents an experimental characterization of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The aim of the study is to find some current characteristics, which can be significant for the purpose of arc detection. The arcing current signal is analyzed in both time and frequency domain. For the AC analysis, the test conditions are chosen in accordance with the “unwanted tripping tests” and the “operation inhibition tests” reported in the Standard UL 1699. The DC study is carried out on the currents waveforms acquired during some on-field tests on a PV plant. Starting from the study herein presented, the authors have found that is it pos…